Description

 

 

For the ordinary person in the extraordinary moment, exceptional ease of use in 3 different published studies¹,²,³

Available without a prescription,4 the HeartStart OnSite Defibrillator is designed with innovative technology, based on extensive research and user feedback, that has produced a defibrillator so easy to set up and use that you can potentially save the life of a co-worker, friend, or anyone else stricken with sudden cardiac arrest.

 

Weighing just 3.3 lbs., this small and lightweight defibrillator can be easily carried to the victim’s side.

 

Using clear, natural voice instructions, the HeartStart OnSite Defibrillator guides you through each step of defibrillation. Designed to not slow you down or leave you behind, it paces and adapts voice instructions to your actions every step of the way. It even reminds you to call emergency medical services (EMS). On-demand CPR Coaching helps the stressed user recall their training.

 

  • Ready when needed. Every meticulously built HeartStart OnSite Defibrillator goes through a 120 point test before it leaves the factory. On the job, the OnSite automatically conducts self-tests every single day, not just weekly. It performs over 80 different tests in all. Even the pads are tested for readiness.

 

  • Effective. Philips pioneered the use of biphasic waveforms in external defibrillators. The electric medicine delivered by the HeartStart OnSite has been rigorously studied, with more than 40 studies demonstrating high first shock efficacy and effectiveness across the full spectrum of patients. Philips SMART Biphasic therapy uses a unique combination of high current to maximize effectiveness and a lower energy dose to minimize side effects that are harmful to a fragile heart. The result – the HeartStart OnSite delivers its maximum shock strength starting with the first shock.

 

  • Make the most of CPR. Recent studies 5,6,7,8 have shown that CPR is even more vital to survival than previously realized. Yet its benefits dissipate in seconds. Delivering a shock quickly after chest compressions is critical. The HeartStart OnSites Quick Shock feature delivers therapy in just 8 seconds (typical) after chest compressions. Other devices can take 2 or 3 three times that, reducing the likelihood of shock success, and potentially, survival.

 

  • Give your early defibrillation program the best chance for success. The HeartStart OnSite Ready-Pack configuration arrives to you virtually ready-to-rescue out of the box, with device pre-installed in carry case, and battery and pads pre-installed in the device.  The Ready-Pack is designed to be the simplest-to-deploy AED, giving you the peace of mind that it is deployed correctly, with less effort.  The simple and welcoming set-up and maintenance instructions are designed to take the intimidation out of owning a defibrillator. 

    With HeartStart AED Services Program Management (available in the US), Philips experts can draw on a wealth of experience to help you get your program started on the right foot, with pre-implementation consulting and site assessments. We can help manage your everyday needs, including medical direction from a licensed physician, AED/CPR training, web-based program management, and case management software.

 

 

1. Andre et al, Prehospital Emergency Care 2004; 8:284-291.

2. Eames et al, Resuscitation 58 (2003); 25-30.

3. Fleischhackl et al, Resuscitation 62 (2004); 167-174.

4. In the US. Defibrillators are just one aspect of a well-planned resuscitation program. Philips recommends medical oversight of early defibrillation programs by a physician or other authorized medical practitioner.

5. Cobb LA, et al. JAMA. 1999; 281(13):1182-1188

6. Wik L, et al. JAMA. 2003 Mar 19; 289(11):1389-1395

7. Yu T, et al. Circulation. 2002; 106:368-372

8. Eftestol T, et al. Circulation. 2002;105:2270-2273

 

Product Specifications

 

Defibrillator Number

HeartStart M5066A

Defibrillator Family

HS1

How Supplied

Defibrillator, battery (one, preinstalled), SMART Pads (one, preinstalled), Set-up/Maintenance guide with expiration date tags, Owner’s Manual, Quick Reference Guide.

HeartStart Onsite (HS1) Ready-Pack option R01: Defibrillator inside carry case, battery (one, pre-installed), SMART Pads (one set pre-installed plus spare set in carry case), Set-up/Maintenance guide with expiration date tags, Owner’s Manual, Quick Reference Guide.

Waveform

Truncated Exponential Biphasic. Waveform parameters adjusted as a function of each patient’s impedance.

Therapy

Adult defibrillation peak current: 32A (150J nominal) into a 50 ohm load. Pediatric defibrillation (with optional Infant/Child SMART Pads Cartridge): 19A (50J nominal) into a 50 ohm load.

Shock-to-Shock Cycle Time

Typically less than 20 seconds between shocks in a series.

Quick Shock

Able to deliver a chock after the end of a CPR interval, typically in eight seconds.

Voice Instructions

Detailed voice messages guide responder through use of the defibrillator.

CPR Coaching

Instructions for adult and infant/child CPR available at user’s option.

Shock Delivery

Via adhesive pads placed on patient’s bare skin as illustrated on pads.

Controls

Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button

 

Indicators

Ready light; blue i-button; caution light

 

Physical Requirements

 

Sealing

Solid objects per EN60529 class IP2X Drip-proof per EN60529 class IPX1

Temperature

Operating: 32º - 122º F (0º - 50º C)

Standby: 50º - 109º F (10º - 43º C)

Humidity

Operating: 0% to 95% relative, non-condensing

Standby: 0% to 75% relative, non-condensing

Altitude

Operating: 0 to 15,000 ft (0 to 4,500 m)

Standby: 0 to 8,500 ft > 48 hours and 8,500 to 15,000 feet < 48 hours

Shock/Drop

Abuse

Withstands 1 meter drop to any edge, corner or surface.

 

Vibration

Meets EN1789 random and swept sine, road ambulance specification in operating and standby states.

EMI (Radiated/

Immunity)

Meets EN55011 Group 1 Level B Class B and

EN61000-4-3.

 

Patient Analysis System

 

Patient Analysis

Evaluates patient ECG to determine if a rhythm is shockable. Rhythms considered shockable are ventricular fibrillation (VF) and certain ventricular tachycardias (VT) associated with lack of circulation. For safety reasons, some VT rhythms associated with circulation will not be interpreted as shockable, and some very low-amplitude or low-frequency rhythms will not be interpreted as shockable VF.

Sensitivity/

Specificity

Meets AAMI DF80 guidelines and AHA recommendations for adult defibrillation (Circulation 1997;95:1677-1682).

Artifact Detection

The effects of pacemaker artifact and electrical noise are minimized with artifact detection.

 

Battery Type

(M5070A)

9 Volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells.

Capacity

Minimum 200 shocks or 4 hours of operating time

(EN 60601-2-4:2003)

Install-By-Date

Battery is labeled with an install-by date of at least five years from date of manufacture.

Standby Life

Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified standby Temperature range, assuming one battery insertion test and no defibrillation uses.)

 

SMART Pads

 

Adult SMART Pads Cartridge

M5071A defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over.

Infant/Child SMART Pads Cartridge

M5072A defibrillation pads for patients under 8 years of age or 55 lbs. (25 kg). Rx only.

Energy Delivered

 

Adult: nominal 150 Joules into a 50 ohm load

Infant/Child: nominal 50 Joules into a 50 ohm load

How Supplied

 

Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution.

Active Surface Area

13.2 in² (85 cm²) each

Cable Length

 

Adult pads: 54 in (137.1 cm)

Infant/Child pads: 40 in (101.6 cm)

Use-by Date

Cartridge is labeled with a use-by date of at least two years from date of manufacture.

 

Training Pads

 

Adult Training Pads Cartridge

M5073A

 

Infant/Child Training Pads Cartridge

M5074A

 

Function

Special pads put HeartStart OnSite into training mode and disable its energy delivery capability. Training pads feature 8 real-world training scripts. Used with training mat (included) or with adapters on manikins.

 

Automated and User Activated Self-Tests

 

Daily Automatic Self-Tests

Tests internal circuitry, waveform delivery system, pads cartridge and battery capacity.

Pads Integrity Test

Specifically tests readiness-for-use of pads (gel moisture).

Battery Insertion Test

Upon battery insertion, extensive automatic self-tests and user-interactive test check device readiness.

Status Indicator

Blinking green "Ready" light indicates ready for use. Audible “chirp” indicates need for maintenance.

 

Data Recording and Transmission

 

Infared

Wireless transmission of event data to a PC or Palm® PDA, using the IrDA protocol.

Data Stored

First 15 minutes of ECG and the entire incident’s events and analysis decisions.

Reviews

There are yet no reviews for this product.

Subscribe to our full RSS feeds

Network with us on LinkedIn

Visit with us on Facebook

Keep up to date on Twitter

Share our site on StumbleUpon

Contact Us

We're excited to hear from you!

You can contact us via our Contact Page. If you'd prefer to give us a ring you can always call us at: 1-800-651-9290

Our Address

Phoenix, AZ, United States